logoooo image
queen appointment warrent raster

By Appointment to Her Majesty The Queen Manufacturers of Wood Finishes Morrells Wood Finishes Ltd Stockport

xerofire® Colour Fire Retardant System

xerofire® Fire Retardant wood finishing systems from Morrells are class-leading systems, providing a high quality, opaque, furniture-grade finish with National Fire Class 0 accreditation as well as EN Euro Reaction to Fire Class B-s1,d0, the best possible Euro reaction to fire performance rating for a system of this type.

  • Fire Class 0 and Euro Fire Class B-s1,d0 furniture-grade wood finishing system
  • Fire resistant, fire proof paint system
  • Fire rated system for spray application

A professional wood finishing system formulated to upgrade (or maintain) the fire-rating of a wide variety of wood-based substrates, including veneered panels, solid hard- and softwoods, plywood, MDF and wood-composite boards. The xerofire® Colour Fire Retardant Coatings system comprises of a 2K waterborne white primer in combination with a 2K acid-catalyst pigmented topcoat providing a high quality, furniture-grade finish in your choice of colour.

Scope for Use

xerofire® Colour fire retardant paint system provides an exceptional finish and is suitable for use with most solid timbers, veneers, MDF and composite boards, giving the architect, specifier and designer a wide range of substrate options.

xerofire® is suitable for use with substrates that meet the following parameters:

  1. Thickness of at least 12mm
  2. Density of at least 510kg/m3
  3. Rating of at least D-s2,d0

xerofire® Colour Fire Retardant System

  1. xerofire® White Primer - a white waterborne fire retardant primer for use under xerofire® Colour topcoat
  2. xerofire® Colour Topcoat - a pigmented acid-catalysed pigmented topcoat for use over xerofire® Prime, available in your choice of colour

xerofire® Colour Fire Retardant Primer

A two-pack waterborne white primer designed to retard the propagation and spread of fire to Fire Class B-s1,d0 and National Class 0. This primer has not been designed to be fully opaque.

During a fire, the fire retardant primer swells to form an insulating charcoal layer. This layer prevents oxygen and heat from reaching the substrate, preventing ignition:

  1. Heat initiates degradation of the coating at around 250°C
  2. The primer reacts to form char
  3. The char expands
  4. Expansion prevents heat from reaching substrate
  5. Char eventually solidifies

xerofire® Colour Topcoat

A two-pack acid-catalyst furniture grade pigmented topcoat rated to FIRA 6250 Severe Use. Designed to give an exceptional, furniture-grade finish over xerofire® White Primer. xerofire® Colour topcoat can be colour-matched to almost any paint sample or swatch choice.

 

A Statement of Supply is issued with each job relevant to the surface area to be coated and the quantity of product supplied.

Please contact Technical Services at 0161 406 5300 or consult the data sheet for full application guidelines. The guidelines below are a summary only and do not contain all required information.

Usage

  1. Apply coat 1 of freshly mixed xerofire® Prime
  2. Apply coat 2 of freshly mixed xerofire® Prime
  3. Lightly denib with 240/320G sandpaper
  4. Apply 1 coat of xerofire® Colour Topcoat

Accreditation

  • Euro Fire Class B-s1,d0
  • Fire Class 0 and BS 476 Part 6 and 7
  1. BS 476: Part 6: 1989 +A1: 2009 – Method of Test for Fire Propagation of Products – Report Number: 315455 issued 25th April 2012 by Exova Warrington. Reviewed (402251) by Exova Warrington 13th July 2018.
  2. BS 476: Part 7: 1997 – Method for Classification of the Surface Spread of Flame of Products – Report Number: 315456 issued 25th April 2012 by Exova Warrington. Reviewed (402252) by Exova Warrington 13th July 2018.
  3. EN 13501-1: 2007 +A1 :2009 “Euro” Classification B-s1,d0 – Report Number 412843 issued 10th June 2019 by Warringtonfire.

The user should consider the Fire Retardant Accreditation for this product range as a guideline only. The tests conducted encompass the whole finishing system which may comprise additionally of substrate, adhesive, veneer and coating, and not just the coating. Application methods and coating weights are also factors which can influence fire retardancy.

It is the responsibility of the user to ensure that their specific system/application achieves/maintains the required Fire-Retardant rating.

xerofire® has received the highest rating for Euro Fire Class B of s1,d0

  • s1 - little or no smoke propagation
  • d0 - no flaming droplets or particles in the first 10 minutes

xerofire® complies with the requirements for Fire Class 0 defined in Appendix A paragraph 13 of Approved Document B “Fire Safety” to the Building Regulations and has achieved the Euro reaction to fire classification of Euro Fire Class B-s1,d0 xerofire® official Exova FR Certification/Accreditation Reports:

  1. EN 13501-1: 2007 +A1 :2009 “Euro” Classification B-s1,d0 – Report Number 412843 issued 10th June 2019 by Warringtonfire
  2. BS 476: Part 6: 1989 +A1: 2009 - Method of test for Propagation of Products - Report Number: 315455 issued 25th April 2012 by Exova Warrington
  3. BS 476: Part 7: 1997 - Method for Classification of the Surface Spread of Flame of Products - Report Number: 315456 issued 25th April 2012 by Exova Warrington

xerofire® has been used in well-known places: Starbucks, Manchester City FC, Tottenham Hotspur FC, Birmingham Library, Heathrow Terminals 4 & 5, The National Theatre, Frankie & Benny’s, Waterloo Underground Station, the Facebook Offices and The Royal Barge. 

Contact Technical Service for more information at 0161 406 5300. See the rest of the Architectural Coatings range, or view our Interior Lacquers.

Product Codes

7XOP/800 xerofire® Primer Part A
7XOP/400 xerofire® Primer Part B
7XR/000 xerofire® Primer Retarder
7X/* xerofire® Colour Topcoat
7CAT/457 xerofire® Colour Topcoat Catalyst
7XCL/000 xerofire® Cleaner

MSDS

Visit our Data Sheet page for access to all available data sheets.

Input your information below to begin download.


Usage

Please contact Technical Services at 0161 406 5300 for more information.

A Statement of Supply is issued with each job relevant to the surface area to be coated and the quantity of product supplied.

Please contact Technical Services at 0161 406 5300 or consult the data sheet for full application guidelines. The guidelines below are a summary only and do not contain all required information.

  1. Apply 1 coat of xerofire® Isolator
  2. Denib with 320g
  3. Apply coat 1 of mixed/reacted xerofire® Basecoat
  4. Apply coat 2 of freshly mixed/reacted xerofire® Basecoat
  5. Lightly denib with 320/400g sandpaper
  6. Apply 1 coat of xerofire® Clear Topcoat (no more than 1 coat is required)

Accreditation

BS 476: Part 6: 1989 +A1: 2009 – Method of Test for Fire Propagation of Products – Report Number: 315455 issued 25th April 2012 by Exova Warrington. Reviewed (402251) by Exova Warrington 13th July 2018.

BS 476: Part 7: 1997 – Method for Classification of the Surface Spread of Flame of Products – Report Number: 315456 issued 25th April 2012 by Exova Warrington. Reviewed (402252) by Exova Warrington 13th July 2018.

EN 13501-1: 2007 +A1 :2009 “Euro” Classification B-s1,d0 – Report Number 412843 issued 10th June 2019 by Warringtonfire.

The user should consider the Fire Retardant Accreditation for this product range as a guideline only. The tests conducted encompass the whole finishing system which may comprise additionally of substrate, adhesive, veneer and coating, and not just the coating. Application methods and coating weights are also factors which can influence fire retardancy.

It is the responsibility of the user to ensure that their specific system/application achieves/maintains the required Fire-Retardant rating.

xerofire® has received the highest rating for Euro Class B of s1,d0

  • s1 - little or no smoke propagation
  • d0 - no flaming droplets or particles in the first 10 minutes

xerofire® complies with the requirements for Class 0 defined in Appendix A paragraph 13 of Approved Document B “Fire Safety” to the Building Regulations and has achieved the Euro reaction to fire classification of Euro Class B-s1,d0 xerofire® official Exova FR Certification/Accreditation Reports:

  1. EN 13501-1: 2007 +A1 :2009 “Euro” Classification B-s1,d0 – Report Number 412843 issued 10th June 2019 by Warringtonfire

  2. BS 476: Part 6: 1989 +A1: 2009 - Method of test for Propagation of Products - Report Number: 315455 issued 25th April 2012 by Exova Warrington

  3. BS 476: Part 7: 1997 - Method for Classification of the Surface Spread of Flame of Products - Report Number: 315456 issued 25th April 2012 by Exova Warrington

xerofire® has been used in well-known places: Starbucks, Manchester City FC, Tottenham Hotspur FC, Birmingham Library, Heathrow Terminals 4 & 5, The National Theatre, Frankie & Benny’s, Waterloo Underground Station, the Facebook Offices and The Royal Barge. 

Contact Technical Service for more information at 0161 406 5300. See the rest of the Architectural Coatings range, or view our Interior Lacquers.

Please contact Technical Services at 0161 406 5300 for more information.

A Statement of Supply is issued with each job relevant to the surface area to be coated and the quantity of product supplied.

Please contact Technical Services at 0161 406 5300 or consult the data sheet for full application guidelines. The guidelines below are a summary only and do not contain all required information.

Usage - the guidelines below are a summary only and do not contain all required information.

  1. Apply 1 coat of xerofire® Isolator
  2. Denib with 320g
  3. Apply 1 coat of mixed/reacted xerofire® Basecoat
  4. Lightly denib with 320/400g sandpaper
  5. Apply 1 coat of xerofire® Clear Topcoat (no more than 1 coat is required)

Please contact Technical Services at 0161 406 5300 for more information.

A Statement of Supply is issued with each job relevant to the surface area to be coated and the quantity of product supplied.

Please contact Technical Services at 0161 406 5300 or consult the data sheet for full application guidelines. The guidelines below are a summary only and do not contain all required information.

Usage - the guidelines below are a summary only and do not contain all required information.

  1. Apply coat 1 of freshly mixed xerofire® Prime
  2. Apply coat 2 of freshly mixed xerofire® Prime
  3. Lightly denib with 240/320G sandpaper
  4. Apply 1 coat of xerofire® Colour Topcoat (no more than 1 coat is required)

Accreditation

BS 476: Part 6: 1989 +A1: 2009 – Method of Test for Fire Propagation of Products – Report Number: 315455 issued 25th April 2012 by Exova Warrington. Reviewed (402251) by Exova Warrington 13th July 2018.

BS 476: Part 7: 1997 – Method for Classification of the Surface Spread of Flame of Products – Report Number: 315456 issued 25th April 2012 by Exova Warrington. Reviewed (402252) by Exova Warrington 13th July 2018.

EN 13501-1: 2007 +A1 :2009 “Euro” Classification B-s1,d0 – Report Number 412843 issued 10th June 2019 by Warringtonfire.

The user should consider the Fire Retardant Accreditation for this product range as a guideline only. The tests conducted encompass the whole finishing system which may comprise additionally of substrate, adhesive, veneer and coating, and not just the coating. Application methods and coating weights are also factors which can influence fire retardancy.

It is the responsibility of the user to ensure that their specific system/application achieves/maintains the required Fire-Retardant rating.

xerofire® has received the highest rating for Euro Class B of s1,d0

  • s1 - little or no smoke propagation
  • d0 - no flaming droplets or particles in the first 10 minutes

xerofire® complies with the requirements for Class 0 defined in Appendix A paragraph 13 of Approved Document B “Fire Safety” to the Building Regulations and has achieved the Euro reaction to fire classification of Euro Class B-s1,d0 xerofire® official Exova FR Certification/Accreditation Reports:

  1. EN 13501-1: 2007 +A1 :2009 “Euro” Classification B-s1,d0 – Report Number 412843 issued 10th June 2019 by Warringtonfire

  2. BS 476: Part 6: 1989 +A1: 2009 - Method of test for Propagation of Products - Report Number: 315455 issued 25th April 2012 by Exova Warrington

  3. BS 476: Part 7: 1997 - Method for Classification of the Surface Spread of Flame of Products - Report Number: 315456 issued 25th April 2012 by Exova Warrington

xerofire® has been used in well-known places: Starbucks, Manchester City FC, Tottenham Hotspur FC, Birmingham Library, Heathrow Terminals 4 & 5, The National Theatre, Frankie & Benny’s, Waterloo Underground Station, the Facebook Offices and The Royal Barge. 

Contact Technical Service for more information at 0161 406 5300. See the rest of the Architectural Coatings range, or view our Interior Lacquers.